Ravel 4 Zone Fire Alarm system
Ravel 4 Zone Fire Alarm system
- Product Code : Ravel 4 Zone Fire Alarm system
- Availability : In Stock
-
₹ 12,990.00
- Ex Tax :₹ 12,990.00
Product Overview
RE-104 is a right blend of affordable design and quality with latest technology for fire alarm control panels. This microprocessor based conventional Fire Alarm Control panel, is designed for small size commercial buildings and small scale industries. RE-104 model is an user friendly 4 zone standalone control panel, with optional zone wise Sounder/Contact respectively.
Special Features
- Switched Mode Power Supply.
- Modular Construction, Serviceable.
- Surface Mount Technology.
- Battery polarity & deep discharge protection.
Features
- As per IS -15908: 2011 Standard.
- 16 X 2 Dot Matrix LCD Display.
- Standby battery backup with built in charging.
- Fire / Fault status in unambiguous colored LED indication.
- Switch Mode Power Supply.
- Tactile Keypad for easy panel operation.
- System ON indication.
- Main, Standby status indication.
- Low Battery visual warning with audible tone.
- Relay output for actuators, for Fire and Fault.
- Lamp Test facility
- Zone wise one man Walk Test Facility.
- Zone wise Isolation facility with loop voltage cut off.
- Compatible to all type of Conventional Detectors.
- Optional Zone Wise Sounder / Zone Wise Contact.
Electrical Specification
Primary Power
120 / 220VAC + 10% -15%, 60 / 50 Hz. 60W
Standby Power
24VDC (2 Nos of 12V, 7Ah Sealed Lead acid battery).
Quiescent current : 55mA
Operating Condition
Operating Temperature - 0 - 49° C/32-120° F.
Storage Temperature - 0 to 60 C
Relative Humidity - 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.
Charging Circuit
Charging Voltage 28.0V, ± 2%
Charging Current 0.5 A (Max.).
Notification Appliance Circuits
Class B wiring
Operating Nominal Voltage: 24VDC
Current for NACs : 0.6 Amp
End-Of-Line Resistor : 4K7, 1/4 watt
Common Relays
Type | Form C |
No of Relays | 3 |
Relay Contact Rating | 2Amps @ 30 VDC, 0.5Amps @125VAC. |
Power Factor | 1.0 |
Initiating Device Circuits (Zone Circuit)
All zones are Class B wiring Normal Operating Voltage | 14- 21 VDC |
Alarm Current | 15 - 30 mA |
Short Circuit Current | 42 mA Maximum |
Loop resistance | 50 ohms Maximum |
End-Of-Line Resistor | 4.7 K, 1/4 watt |
Standby Current | 6.8 mA (2.4 mA for Detectors) |
Mounting Details
Mechanical Specification
Dimensions | (350W X 250H X 100D) |
Color | Red / White |
Construction | 18 Gauge (1.22mm) CRCA sheet with powder-coated Finish |
IP Rating | IP50 |
Cable Entry | 11xø19mm Knockout in top of the cabinet |
Wiring Diagram
Ordering Information:
MODEL | DESCRIPTION |
RE-104-W | 4 ZONE Fire Alarm Panel |
RE-104-R | 4 ZONE Fire Alarm Panel |
Compatible Devices
MODEL | DESCRIPTION |
RE-316S-2L | Photoelectric Smoke detector with base. |
RE-316H-2L | Heat detector with base. |
RE-316SH-2L | Photoelectric & Heat detector with base |
RE-716 MR | Conventional Manual Call Point. |
RE- 24 CS | Conventional Sounder. |